Phoenix Contact
- RS庫存編號:
- 666-7072
- 製造零件編號:
- 2981716
- 製造商:
- Phoenix Contact
單價 個**
TWD701.00
(不含稅)
TWD736.05
(含稅)
40 現貨庫存,可於6工作日發貨。*
* 交貨日期可能會根據您選擇的數量和交貨地址而變更。
訂單金額滿 TWD2,857.00 (未稅) 即可享受 免費 送貨服務
單位 | 每單位 |
---|---|
1 + | TWD701.00 |
** 參考價格
- RS庫存編號:
- 666-7072
- 製造零件編號:
- 2981716
- 製造商:
- Phoenix Contact
- COO (Country of Origin):
- DE
Multi-application Modular System - PSR-SPP Series
This can be quickly and reliably assembled to form a tailor-made safety solution. To connect using TBUS correctly you will need one PSR-TBUS per module. For the last additional module use one PSR-TBUS-TP instead, this will close the feedback loop. The interface module is used for the connection of up to four safety sensors with NC/NO contacts to the safety relay PSR-SDC4, with screw connection.
Features and Benefits
Quick system extension up to 10 modules, offering a safety system with up to 42 contacts
Automatic identification of desired operating mode, no need to set switches or define parameters
The system is based on a master relay (PSR-SDC) that monitors e-stops, guard doors (interlock or non-contact) and optical devices (e.g. light curtains)
Safe cross-wiring with T-BUS renders the usual cross-wiring of supply voltage, enable signal and confirmation path redundant. Making commissioning and future expansion simple
24Vdc supply voltage
Semiconductor output
Depending on the wiring Safety category 2 or 4 can be maintained
One or Two channel switches are used for control
Note: The device has a rear interface for the DIN Rail connector T-BUS. Via this T-BUS interface extension devices PSR-URM4-B (undelayed contacts) and PSR-URD (drop-out delay contacts) can be controlled and monitored over one channel. These in combination form a T-BUS unit, the feedback path must be connected to the final (right hand) extension device (see datasheet for more details) or by using connection plug PSR-TBUS-TP
Automatic identification of desired operating mode, no need to set switches or define parameters
The system is based on a master relay (PSR-SDC) that monitors e-stops, guard doors (interlock or non-contact) and optical devices (e.g. light curtains)
Safe cross-wiring with T-BUS renders the usual cross-wiring of supply voltage, enable signal and confirmation path redundant. Making commissioning and future expansion simple
24Vdc supply voltage
Semiconductor output
Depending on the wiring Safety category 2 or 4 can be maintained
One or Two channel switches are used for control
Note: The device has a rear interface for the DIN Rail connector T-BUS. Via this T-BUS interface extension devices PSR-URM4-B (undelayed contacts) and PSR-URD (drop-out delay contacts) can be controlled and monitored over one channel. These in combination form a T-BUS unit, the feedback path must be connected to the final (right hand) extension device (see datasheet for more details) or by using connection plug PSR-TBUS-TP
Note
The device has a rear interface for the DIN Rail connector T-BUS. Via this T-BUS interface extension devices PSR-URM4-B (undelayed contacts) and PSR-URD (drop-out delay contacts) can be controlled and monitored over one channel. These in combination form a T-BUS unit, the feedback path must be connected to the final (right hand) extension device (see datasheet for more details) or by using connection plug PSR-TBUS-TP.