Alpha Wire Xtra-Guard 2 Performance Cable Control Cable, 2 Cores, 1.23 mm² 16 AWG, Unscreened, 30 m, Black Polyvinyl

小計(1 卷,共 30 米)*

TWD10,306.00

(不含稅)

TWD10,821.30

(含稅)

Add to Basket
選擇或輸入數量
暫時缺貨
  • 10 件從 2026年5月19日 起裝運發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
每卷
每米*
1 +TWD10,306.00TWD343.533

* 參考價格

RS庫存編號:
873-1276
製造零件編號:
25072 BK005
製造商:
Alpha Wire
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Alpha Wire

Series

Xtra-Guard 2 Performance Cable

Product Type

Control Cable

Number of Cores

2

Conductor Material

Tin Copper Wire

Jacket Material

Polyvinyl Chloride

Jacket Colour

Black

Armoured

Yes

Screened/Unscreened

Unscreened

Cable Length

30m

Minimum Operating Temperature

-30°C

Standards/Approvals

UL, CE, CSA

Maximum Operating Temperature

90°C

Hazardous Area Certification

No

American Wire Gauge

16AWG

Fire Behaviour

Flame Retardant

Belden Xtra-Guard 2 Performance Cable Series Control Cable, 30m Cable Length, 2 Cores - 25072 BK005


This control cable is designed for industrial signal and control circuits in automation and electrical installations. It comprises two conductors with tinned copper strands and a black PVC outer sheath, providing a flexible connection for equipment operating within a wide temperature range. The cable is unscreened and rated for 300V use, making it suitable for general-purpose control wiring where a flame-retardant construction is required.

Features & Benefits


• 19-strand tinned copper offers enhanced flexibility for routing
• Flame-retardant jacket reduces fire propagation risk in installations
• Rated 300V to support common control-voltage systems
• Operating range -30°C to 90°C enables varied environmental use
• Unscreened design simplifies connections for non‑noisy circuits
• PVC outer sheath provides chemical and abrasion resistance

Applications


• Suitable for factory automation control panels and wiring
• Ideal for motor starter and relay interconnections
• Used for sensor and actuator cabling in machinery
• Can be used for general-purpose control runs in plant wiring
• Used with Terminal blocks and cable assemblies for equipment racks

What conductor construction ensures flexibility for tight bends?


Each conductor contains 19 tinned copper strands, which reduces stiffness and aids installation around bends.

How should bend radius be managed during installation?


Maintain a minimum bend radius of 10x the cable diameter to prevent conductor stress.

What labelling or marking is present on the cable?


The jacket is printed with manufacturer identification, part details and sequence footage marking for traceability.

What mechanical loads can the cable tolerate during pull‑in?


Maximum permissible pull tension is 41 lb during installation to avoid damage.

Which regulatory designations apply to its construction?


The cable conforms to recognised AWM styles and meets fire test and low‑voltage directives applicable to control wiring.

相關連結