GEORGIN 1 Channel Double Zener Barrier, ATEX
- RS庫存編號:
- 230-9461
- 製造零件編號:
- BZG788PLUS
- 製造商:
- GEORGIN
10 現貨庫存,可於6工作日發貨。
單價(不含稅) 1 盒 1 套
TWD6,433.00
(不含稅)
TWD6,754.65
(含稅)
Box(es) | Per Box |
---|---|
1 + | TWD6,433.00 |
- RS庫存編號:
- 230-9461
- 製造零件編號:
- BZG788PLUS
- 製造商:
- GEORGIN
產品概覽和技術數據資料表
法例與合規
- COO (Country of Origin):
- FR
產品詳細資訊
Zener barriers contribute to the intrinsic safety [Ex i] and are installed in safe areas. Their mission is to limit the level of energy that may appear in an electric circuit routed through a potentially explosive area, whatever the connection established upstream of the barrier.
A barrier is made up of:
- resistors that limit the current
- Zener diodes that limit the voltage
- fuses that protect the components
A barrier is made up of:
- resistors that limit the current
- Zener diodes that limit the voltage
- fuses that protect the components
When a fault voltage is applied across the input terminals of the barrier, the voltage that may appear in the explosive zone is limited by a Zener diode, which is in turn protected by a fuse.
The current is limited to an acceptable value by the resistor.
They can be installed in zone 2, thanks to the Ex nA certification in an IP 54 housing.
The current is limited to an acceptable value by the resistor.
They can be installed in zone 2, thanks to the Ex nA certification in an IP 54 housing.
Zener barrier for analogic signals
Polyester enclosure / DIN Rail mounting
For floating potential wiring
3/4: U0=28V I0=83.97mA P0=587.79mW
2/3: Ua=26.8V Ifm=50mA RL=311.3ohm
Number of channels: 1
Screw terminals
Option: Without
Polyester enclosure / DIN Rail mounting
For floating potential wiring
3/4: U0=28V I0=83.97mA P0=587.79mW
2/3: Ua=26.8V Ifm=50mA RL=311.3ohm
Number of channels: 1
Screw terminals
Option: Without
ATEX / IECEx informations:
INERIS 11ATEX0024X / IECEx INE11.0009X
Group II (surface) - category (1) G/D
II(1) GD [Ex ia Ga] IIC, IIB or [Ex iaD Da] IIIC
II3(1) G Ex nA [ia Ga] IIC T4 Gc
Installation in safe zone or zone 2
For equipment installed in zone 0,1,2,20,21,22
See leaflet for a safe use
INERIS 11ATEX0024X / IECEx INE11.0009X
Group II (surface) - category (1) G/D
II(1) GD [Ex ia Ga] IIC, IIB or [Ex iaD Da] IIIC
II3(1) G Ex nA [ia Ga] IIC T4 Gc
Installation in safe zone or zone 2
For equipment installed in zone 0,1,2,20,21,22
See leaflet for a safe use
規格
屬性 | 值 |
---|---|
Number of Channels | 1 |
Barrier Type | Zener Barrier |
Maximum Voltage | 28V |
Hazardous Area Certification | ATEX |
Minimum Operating Temperature | -20°C |
Maximum Current | 83,97mA |
Maximum Operating Temperature | +60°C |
Series | BZG |