- RS庫存編號:
- 415-200
- 製造零件編號:
- TIS40
- 製造商:
- Eaton
- RS庫存編號:
- 415-200
- 製造零件編號:
- TIS40
- 製造商:
- Eaton
產品概覽和技術數據資料表
法例與合規
不適用
產品詳細資訊
Red Spot™ Range, Type T HBC
As the fuse allows for the starting surge of a motor its full load current must not exceed the lesser of the dual current rating. e.g. 20 M25 must not have a continuous load of greater than 20A
Features and Benefits
Breaking capacity 80kA ac 40kAdc
Rated up to 550Vac/ 250Vdc (Type A1) & 660Vac/ 460Vdc (Type A2)
General purpose (gG) and dual motor rated (gM) types
Low power dissipation
660Vac rated (A1 types 415Vac)
ASTA 20 certified
Rated up to 550Vac/ 250Vdc (Type A1) & 660Vac/ 460Vdc (Type A2)
General purpose (gG) and dual motor rated (gM) types
Low power dissipation
660Vac rated (A1 types 415Vac)
ASTA 20 certified
As the fuse allows for the starting surge of a motor its full load current must not exceed the lesser of the dual current rating. e.g. 20 M25 must not have a continuous load of greater than 20A.
Eaton British Standard Fuse, A3, 40A TIS40
Protect your industrial equipment from overcurrent and short circuits with this electrical fuse from Eaton's Red Spot range. This unit falls into the gG (general purpose) and gM (dual motor) categories, meaning it's compatible with both fast-acting and slow-acting electrical systems.
With a 40A current rating and an AC (alternating current) rating of 660V, this component is ideally suited to heavy-duty applications. A high rupture capacity makes it safe for use in high thermal environments. It's commonly used in wiring equipment and dual-motor circuit protection.
With a 40A current rating and an AC (alternating current) rating of 660V, this component is ideally suited to heavy-duty applications. A high rupture capacity makes it safe for use in high thermal environments. It's commonly used in wiring equipment and dual-motor circuit protection.
Features & Benefits
8.7mm wide offset tags for quick and easy connection to fuse holder
Light weight of 57.45g won't place strain on your equipment
High breaking capacity of 80kA for electrical safety
High temperature tolerance prevents arcing due to overcurrent
Light weight of 57.45g won't place strain on your equipment
High breaking capacity of 80kA for electrical safety
High temperature tolerance prevents arcing due to overcurrent
Which fuses are considered to be low voltage?
Low voltage fuses are those that have a voltage rating less than or equal to 1500V.
What are British Standard fuses?
British Standard fuses are made to BS88 standards and normally feature either clip-in, centre or offset tags.
Note
Eaton formerly known as Bussmann
規格
屬性 | 值 |
---|---|
Current Rating | 40A |
Fuse Size | A3 |
Voltage Rating | 660V ac |
Fuse Standard | BS 88-2, IEC 269-2 |
Fixing Centres | 73mm |
Application Category | gG, gM |
Tag Width | 8.7mm |
Fuse Speed | T |
High Rupture Capacity | Yes |
Overall Length | 85.5mm |
Body Diameter | 22.2mm |
Tag Type | Bolted |
Tag Orientation | Offset |
Body Height | 56.4mm |
Fuse Dimensions | 22 x 86mm |
Series | Bussmann |