Omron G9SB Emergency Stop Safety Relay, 24V dc, Dual-Channel, 3 Safety Contacts
- RS庫存編號:
- 757-9301
- 製造零件編號:
- G9SB-3010 DC24
- 製造商:
- Omron
單價(不含稅) 個
TWD6,301.00
(不含稅)
TWD6,616.05
(含稅)
可供預購。*
* 交貨日期可能會根據您選擇的數量和交貨地址而變更。
訂單金額滿 TWD2,857.00 (未稅) 即可享受 免費 送貨服務
單位 | 每單位 |
---|---|
1 + | TWD6,301.00 |
- RS庫存編號:
- 757-9301
- 製造零件編號:
- G9SB-3010 DC24
- 製造商:
- Omron
- COO (Country of Origin):
- CN
G9SB, Safety Relays, Ultra Slim
The Omron G9SB series is an ultra slim safety relay available in either a 17.5mm or 22.5mm housing. The 17.5mm units have 2 or 3 safety contacts and the 22.5mm units have 3 safety contacts and an auxiliary contact.
1 and 2 input channel units
Manual and automatic reset units
Certification up to category 4 according to EN954-1 (depending on the application)
Can also be used with safety sensors F3SN, F3SH, F3S-B, F3STGR, F3SL, F3S-J
Conforms to EN standards (TUV approval)
Manual and automatic reset units
Certification up to category 4 according to EN954-1 (depending on the application)
Can also be used with safety sensors F3SN, F3SH, F3S-B, F3STGR, F3SL, F3S-J
Conforms to EN standards (TUV approval)
Note
When ordering take note of the safety reset mode that is required: Models G9SB**A and G9SB ** B = Auto Reset operation; Models G9SB ** D = Manual Reset operation
Approvals
EN954-1, EN60204-1, UL508, CSA C22.2 No. 14
G9SB Ultra Slim Safety Relays.
• Ultra slim relay module.
• Models with a width of 17.5 mm are available with 2 or 3 poles (safety contacts).
• Models with a width of 22.5 mm with 3 poles (safety contacts).
• 1 and 2 input channels.
• Manual and automatic reset.
• Can be DIN rail mounted.
• Relays with inverse inputs are used when inputting signals from 2 mechanical switches.
• Relays with positive commons are used when inputting signals from a safety sensor or one mechanical switch.
• Conform to EN standards (TUV approval).
• G9SB-3010 is applied to safety category 3 of EN 954-1 if double breaking is used.
• Models with a width of 17.5 mm are available with 2 or 3 poles (safety contacts).
• Models with a width of 22.5 mm with 3 poles (safety contacts).
• 1 and 2 input channels.
• Manual and automatic reset.
• Can be DIN rail mounted.
• Relays with inverse inputs are used when inputting signals from 2 mechanical switches.
• Relays with positive commons are used when inputting signals from a safety sensor or one mechanical switch.
• Conform to EN standards (TUV approval).
• G9SB-3010 is applied to safety category 3 of EN 954-1 if double breaking is used.
Applicable to Safety Sensors.
• Model F3S-B
• Model F3SH
• Model F3S-J
• Model F3SL
• Model F3SN
• Model F3S-TGR
• Model F3SH
• Model F3S-J
• Model F3SL
• Model F3SN
• Model F3S-TGR
Model F3S-TGR Safety Sensors covers a range of articles available within Non-Contact Safety Switches, Light Curtains, Light Beams and Machine Guarding Accessories.
G9SB-3010 DC24 Slim Safety Relay.
• Main contact 3PST-NO (normally open).
• Auxiliary contact SPST-NC (normally closed).
• Direct breaking. (Safety category 3 of EN 954-1 is applied if double breaking is used)
• Auto-reset.
• Rated voltage 24 V dc.
• Operating voltage range 85% to 110% of the rated power supply voltage.
• Power consumption 1.7 W max.
• Input current 60 mA max.
• Resistive load
• Rated load 250 V ac, 5 A. 30 V dc, 5 A.
• Rated carry current 5 A.
• Auxiliary contact SPST-NC (normally closed).
• Direct breaking. (Safety category 3 of EN 954-1 is applied if double breaking is used)
• Auto-reset.
• Rated voltage 24 V dc.
• Operating voltage range 85% to 110% of the rated power supply voltage.
• Power consumption 1.7 W max.
• Input current 60 mA max.
• Resistive load
• Rated load 250 V ac, 5 A. 30 V dc, 5 A.
• Rated carry current 5 A.
Features and Benefits.
• Contact resistance 100 mΩ
• Insulation resistance 100 MΩ mon (at 500 V dc)
• Vibration resistance 10 to 55 to 10 Hz, 0.375 mm single amplitude (0.75 mm double amplitude)
• Shock resistance destruction 300 m/s².
• Shock resistance malfunction 100 m/s²
• Failure rate (P Level) (reference value) 5 V dc, 1 mA
• Always turn OFF the G9SB before connecting an expansion unit.
• If mounting multiple units next to each other the rated current will be 3 A. (do not apply any higher currents)
• Stranded wire 0.2 to 2.5 mm²
• Solid Wire 0.2 to 2.5 mm²
• Screw torque of 0.5 to 0.6 Nm. (incorrect screw tightening can result in a malfunction or generate heat).
• Positive thermistor built onto the circuits detecting short breakdowns.
• Weight 135 g
• Insulation resistance 100 MΩ mon (at 500 V dc)
• Vibration resistance 10 to 55 to 10 Hz, 0.375 mm single amplitude (0.75 mm double amplitude)
• Shock resistance destruction 300 m/s².
• Shock resistance malfunction 100 m/s²
• Failure rate (P Level) (reference value) 5 V dc, 1 mA
• Always turn OFF the G9SB before connecting an expansion unit.
• If mounting multiple units next to each other the rated current will be 3 A. (do not apply any higher currents)
• Stranded wire 0.2 to 2.5 mm²
• Solid Wire 0.2 to 2.5 mm²
• Screw torque of 0.5 to 0.6 Nm. (incorrect screw tightening can result in a malfunction or generate heat).
• Positive thermistor built onto the circuits detecting short breakdowns.
• Weight 135 g
Applications Include.
• Light curtain.
• Light guard.
• Light guard.
屬性 | 值 |
---|---|
Supply Voltage | 24V dc |
Number of Channels | 2 |
Safety Contacts | 3 |
Function | Emergency Stop |
Auxiliary Contacts | 1 |
Safety Category ISO 13849-1 | 3 |
PL ISO 13849-1 | e |
Depth | 112mm |
Series | G9SB |
Width | 18mm |
Performance Level | e |
Length | 100mm |