RS PRO Hydrometer
- RS庫存編號:
- 196-8187
- 製造商:
- RS PRO
單價(不含稅) 個
原價 TWD895.00
您付款
TWD617.00
(不含稅)
TWD647.85
(含稅)
5 "將在 2 工作日發貨 (本地庫存) "*
120 在6 工作日內發貨 (海外庫存)
* 交貨日期可能會根據您選擇的數量和交貨地址而變更。
訂單金額滿 TWD2,857.00 (未稅) 即可享受 免費 送貨服務
單位 | 每單位 |
---|---|
1 + | TWD617.00 |
- RS庫存編號:
- 196-8187
- 製造商:
- RS PRO
不適用
- COO (Country of Origin):
- IT
Battery Hydrometer
If you service automotive batteries, this highly precise battery hydrometer for measuring the state of charge of lead acid batteries when servicing automotive batteries is ideal.
Designed for use in the automotive industry, this battery hydrometer offers a fantastic degree of precision when measuring the state of charge of lead acid batteries when servicing automotive batteries. It is the perfect instrument for measuring the specific gravity of battery electrolyte and it allows each cell to be individually checked at a glance. The high precision scale is in Baume degrees & specific weight with coloured sections for a quick reading.
Designed for use in the automotive industry, this battery hydrometer offers a fantastic degree of precision when measuring the state of charge of lead acid batteries when servicing automotive batteries. It is the perfect instrument for measuring the specific gravity of battery electrolyte and it allows each cell to be individually checked at a glance. The high precision scale is in Baume degrees & specific weight with coloured sections for a quick reading.
Features and Benefits:
High-quality glass tube
Easy reading test results thanks to high-precision scale in Baume degrees and specific weight with coloured sections
A quick and accurate measure of specific gravity of individual cells of a battery
Easy reading test results thanks to high-precision scale in Baume degrees and specific weight with coloured sections
A quick and accurate measure of specific gravity of individual cells of a battery
Typical applications:
A hydrometer is a device Designed for use in the automotive industry, this battery hydrometer offers a fantastic degree of precision when measuring the state of charge of lead-acid batteries when servicing automotive batteries.
For the best and most accurate results remember to clean the hydrometer carefully with water after each use and let it dry before the next use.
FAQ's
What is Specific Gravity?
Hydrometers measure the specific gravity of liquids. Specific gravity is the ratio of the density of the liquid being tested to the density of water. In battery testing, the hydrometer is measuring the specific gravity of the batterys electrolyte. The higher the acid concentration in the electrolyte the higher the specific gravity. Based on the specific gravity you can then tell the state of charge and condition of the battery.
How to read a battery hydrometer?
The typical range of values on the scale is 1.100 to over 1.300. The numbers are specific gravity values or the density of the liquid compared to that of water which has specific gravity designated as 1.000. The typical full–charge reading for an industrial battery is 1.275 (although some may be more so check manufacturers data for the recommended full charge specific gravity reading). A lead–acid battery is ready for recharging when it has reached its 80% discharge point, and this is indicated by a hydrometer reading between approximately 1.140 and 1.180. Battery operation below 1.120 is not recommended.
Handy Tips on using a Hydrometer
Measure more than one cell when checking for state of charge
You might not get an accurate reading right after watering the battery
Battery temperatures affect reading accuracy, electrolyte should be at normal room temperature
For safety reasons wear eye protection
Rinse out hydrometer after using as the residue is corrosive
Hydrometers measure the specific gravity of liquids. Specific gravity is the ratio of the density of the liquid being tested to the density of water. In battery testing, the hydrometer is measuring the specific gravity of the batterys electrolyte. The higher the acid concentration in the electrolyte the higher the specific gravity. Based on the specific gravity you can then tell the state of charge and condition of the battery.
How to read a battery hydrometer?
The typical range of values on the scale is 1.100 to over 1.300. The numbers are specific gravity values or the density of the liquid compared to that of water which has specific gravity designated as 1.000. The typical full–charge reading for an industrial battery is 1.275 (although some may be more so check manufacturers data for the recommended full charge specific gravity reading). A lead–acid battery is ready for recharging when it has reached its 80% discharge point, and this is indicated by a hydrometer reading between approximately 1.140 and 1.180. Battery operation below 1.120 is not recommended.
Handy Tips on using a Hydrometer
Measure more than one cell when checking for state of charge
You might not get an accurate reading right after watering the battery
Battery temperatures affect reading accuracy, electrolyte should be at normal room temperature
For safety reasons wear eye protection
Rinse out hydrometer after using as the residue is corrosive